Hoja de acero en frío del silicio

Technical parameters, project-specific options and a quotation based on your requirements

  • IEC / ANSI / IEEE
  • Factory Test Reports
  • Custom Voltage & Capacity
  • Global Project Support

Transformer product

Hoja de acero en frío del silicio

Se conforma con GB/T 2521 e IEC 60404. Con ventajas básicas de baja pérdida de núcleo y alta permeabilidad magnética, es un material clave para equipos eléctricos modernos de alta eficiencia.

ConfigurationCustom voltage & capacity
StandardsIEC / ANSI / IEEE support
DocumentationFactory test reports
Certifications and documentation: ISO 9001, ISO 14001, ISO 45001, CE, UL
[email protected]
Engineering support for project-specific transformer selection
Custom voltage, capacity, vector group, enclosure and accessories
Factory testing, export documentation and after-sales support

Detailed information

Product details

La lámina de acero al silicio laminado en frío es un acero eléctrico de alto rendimiento producido por proceso de laminación en frío, con un contenido de silicio de 0.5%-3.5%. Después del laminado, recocido y tratamiento de recubrimiento, presenta excelentes propiedades magnéticas. Ampliamente utilizado en la fabricación de núcleos de hierro de equipos electromagnéticos de alta frecuencia y alto rendimiento, como transformadores grandes, motores de precisión y generadores, cumple con GB/T 2521 e IEC 60404. Con ventajas básicas de baja pérdida de núcleo y alta permeabilidad magnética, es un material clave para equipos eléctricos modernos de alta eficiencia.

Características del producto

Hojas de acero de silicio laminado en frío: 30%-50% mayor permeabilidad, 40%-60% menor pérdida de núcleo que los tipos laminados en caliente, estable a 50Hz-400Hz para una mejor eficiencia. Los granos finos y orientados (especialmente orientados al grano) aseguran la uniformidad magnética, reduciendo la vibración/ruido. Superficie superior (tolerancia de ± 0,01mm) para laminación de precisión. Compatible con el procesamiento de alta precisión y apilamiento automatizado para diseños complejos. Revestimiento aislante (≥ 400V desglose) resiste el óxido/calor, cortando la pérdida de corriente de Foucault.



Clasificación del producto

  • Por orientación cristalina: Orientado al grano (textura GOSS, excelente permeabilidad en la dirección de rodadura, pérdida de núcleo ultra baja, para núcleos de transformadores); no orientado (propiedades magnéticas isotrópicas, para rotores y estatores de motor/generador).
  • Por nivel de pérdida de núcleoGrado estándar (p. ej., 35W300, 3,00 W/kg @ 50Hz); grado de alta eficiencia (por ejemplo, 35W250, 2,50 W/kg @ 50Hz); grado de ultra alta eficiencia (por ejemplo, 35W130, 1,30 W/kg @ 50Hz).
  • Por espesor: Ultrafino (0,18mm-0,23mm, para transformadores de alta frecuencia); estándar (0,30mm-0,35mm, de uso general); grueso (0,50mm-0,65mm, para motores grandes).


Servicio post-venta

  • Control de calidad: Cada lote pasa las pruebas de pérdida de núcleo, permeabilidad y adhesión de recubrimiento, con informes de terceros; desviación de pérdida de núcleo ≤ ± 3%.
  • Soporte técnico: Proporciona la simulación del diseño de la base y los servicios del cálculo de la pérdida, ayudando en la optimización de métodos de la laminación para reducir pérdida de la corriente de Foucault.
  • Garantía de suministroHojas orientadas al grano entregadas dentro de 7 días, hojas no orientadas enviadas dentro de 48 horas; admite personalización de corte y suministro de rollo completo.
Designed around your systemConfirm voltage, capacity, frequency and installation conditions with our team.
Built for project reviewReceive a configuration, quotation and documentation matched to the application.

Final technical parameters are confirmed according to the project voltage, capacity, application and applicable standards.

Need a different voltage, capacity or accessory configuration? Send the requirement for a technical review.

From specification to delivery

Support for your transformer project

Transformer selection is more than choosing a capacity. We help align the electrical requirements, documentation and delivery details before production.

01

Define the configuration

Review voltage, capacity, cooling, enclosure, vector group and accessories.

02

Confirm the evidence

Prepare drawings, factory test reports and export documentation for review.

03

Coordinate delivery

Support production coordination, shipment preparation and after-sales communication.

PROJECT EXPERIENCE

See Our Transformer Projects in Action

Explore selected transformer projects delivered for utility, industrial, renewable energy, and infrastructure applications. Each project reflects our experience in engineering, manufacturing, testing, and delivering transformer solutions to meet specific project requirements.

Russia SCB-630~2500 Transformer Project

Russia SCB-630~2500 Transformer Project

Ver detalles
Belarus SFFLZ-62000kVA-115kV Transformer Project

Belarus SFFLZ-62000kVA-115kV Transformer Project

Ver detalles
Uzbekistan SSFZ-16000/110 Transformer Project

Uzbekistan SSFZ-16000/110 Transformer Project

Ver detalles
Indonesia S13-2500/6.3 Transformer Project

Indonesia S13-2500/6.3 Transformer Project

Ver detalles

Preguntas frecuentes

Compruebe nuestro Preguntas frecuentes

Are your transformers ANSI/IEEE compliant?

Yes. All U.S.-bound transformers are designed per ANSI/IEEE C57.12 series. UL listing available upon request.

What is your warranty?

2 years (extendable upon negotiation).

Can you provide third-party test reports?

Yes. We provide complete factory test reports. Third-party witnessed testing can be discussed on a per-project basis.

What is the minimum lead time for emergency orders?

As fast as 15 days for emergency replacements (strategic material reserve).

Do you have a U.S. warehouse or local support?

Main shipping from Shanghai. Remote technical support and on-site service coordination available.

Información y soporte integral

Nuestra sección de preguntas frecuentes cubre productos de transformadores, materiales de aislamiento y especificaciones técnicas, abordando el diseño, las normas de fabricación, el control de calidad y las consultas de logística. Para obtener más asistencia, nuestro equipo técnico está disponible para ayudar.

Contacte con nosotros

PROJECT INQUIRY

Request a transformer quote for Cold-rolled silicon steel sheet

Share the information you already have. Our engineering team will review the requirement and recommend a suitable transformer configuration.

Project-specific configuration Voltage, capacity, cooling and accessories
Technical review and documentation Factory testing and export support available
Global project support Support from initial specification to delivery
[email protected]

Tell us about your project

What do you need us to review?

* Required fields

Your information is used only to respond to this inquiry.

Email