Hoja de acero laminada en caliente del silicio

Technical parameters, project-specific options and a quotation based on your requirements

  • IEC / ANSI / IEEE
  • Factory Test Reports
  • Custom Voltage & Capacity
  • Global Project Support

Transformer product

Hoja de acero laminada en caliente del silicio

Se conforma con estándares como GB/T 5212 e IEC 60404, y ofrece proceso de producción relativamente simple y bajo costo.

ConfigurationCustom voltage & capacity
StandardsIEC / ANSI / IEEE support
DocumentationFactory test reports
Certifications and documentation: ISO 9001, ISO 14001, ISO 45001, CE, UL
[email protected]
Engineering support for project-specific transformer selection
Custom voltage, capacity, vector group, enclosure and accessories
Factory testing, export documentation and after-sales support

Detailed information

Product details

La lámina de acero al silicio laminado en caliente es un tipo de acero eléctrico producido por un proceso de laminación en caliente, con un contenido de silicio que generalmente varía de 0.5% a 4.5%. La adición de silicio puede mejorar las propiedades magnéticas del material. Es adecuado para la fabricación de núcleos de hierro de equipos electromagnéticos con requisitos de baja frecuencia y bajo rendimiento, como motores pequeños, transformadores, inductores, etc. Conforme a estándares como GB/T 5212 e IEC 60404, y presenta un proceso de producción relativamente simple y de bajo costo.

Características del producto

Tiene una menor permeabilidad y mayor pérdida de núcleo que las láminas de acero al silicio laminadas en frío, pero satisface las necesidades básicas a 50Hz-60Hz. Con granos más gruesos, orientación de cristal irregular y propiedades magnéticas desiguales, presenta costos más bajos debido a una producción más simple y una mayor utilización del material. Aunque el plástico es suficiente para cizallar/estampar, su calidad de superficie más pobre reduce la precisión de procesamiento en comparación con los productos laminados en frío. Limitado por el rendimiento magnético, no es adecuado para equipos de alta frecuencia/alto rendimiento como transformadores grandes y motores de precisión.



Clasificación del producto

  • Por contenido de silicio: Chapa de acero de bajo contenido de silicio (contenido de silicio 0.5%-1.0%, baja permeabilidad magnética, alta pérdida de núcleo, adecuada para ocasiones con requisitos de bajo rendimiento); chapa de acero de silicio medio (contenido de silicio 1.0%-3.0%, rendimiento magnético moderado, con una amplia gama de aplicaciones); hoja de acero del alto-silicio (contenido 3.0%-4.5%, permeabilidad magnética mejorada del silicio, Pérdida de núcleo relativamente reducida, adecuada para equipos con ciertos requisitos de rendimiento magnético).​
  • Por espesor: Calibre grueso (0,5mm-1,0mm, buena rigidez, adecuado para grandes estructuras de núcleo simple); calibre delgado (0,35mm-0,5mm, flexibilidad ligeramente mejor, se puede utilizar en motores pequeños y otros equipos).​
  • Por estado de superficie: Chapa de acero al silicio laminado en caliente sin recubrimiento (sin tratamiento especial en la superficie, necesita un tratamiento de prevención de la oxidación antes de su uso); chapa de acero al silicio laminado en caliente pintado (superficie recubierta con pintura aislante, que puede mejorar el rendimiento del aislamiento y la resistencia al óxido).


Servicio post-venta

It features strict quality control with each batch undergoing magnetic performance testing (core loss, permeability, etc.), dimensional accuracy and surface quality inspections, accompanied by quality reports to support customer re-inspection; offers technical support including product selection advice, recommending products with suitable silicon content and thickness based on customers' equipment performance needs, and providing processing technology guidance; and ensures supply with regular specifications shipped within 72 hours, special specifications customizable with a 15-20 day delivery cycle, and bulk purchase support.

Designed around your systemConfirm voltage, capacity, frequency and installation conditions with our team.
Built for project reviewReceive a configuration, quotation and documentation matched to the application.

Final technical parameters are confirmed according to the project voltage, capacity, application and applicable standards.

Need a different voltage, capacity or accessory configuration? Send the requirement for a technical review.

From specification to delivery

Support for your transformer project

Transformer selection is more than choosing a capacity. We help align the electrical requirements, documentation and delivery details before production.

01

Define the configuration

Review voltage, capacity, cooling, enclosure, vector group and accessories.

02

Confirm the evidence

Prepare drawings, factory test reports and export documentation for review.

03

Coordinate delivery

Support production coordination, shipment preparation and after-sales communication.

PROJECT EXPERIENCE

See Our Transformer Projects in Action

Explore selected transformer projects delivered for utility, industrial, renewable energy, and infrastructure applications. Each project reflects our experience in engineering, manufacturing, testing, and delivering transformer solutions to meet specific project requirements.

Russia SCB-630~2500 Transformer Project

Russia SCB-630~2500 Transformer Project

Ver detalles
Belarus SFFLZ-62000kVA-115kV Transformer Project

Belarus SFFLZ-62000kVA-115kV Transformer Project

Ver detalles
Uzbekistan SSFZ-16000/110 Transformer Project

Uzbekistan SSFZ-16000/110 Transformer Project

Ver detalles
Indonesia S13-2500/6.3 Transformer Project

Indonesia S13-2500/6.3 Transformer Project

Ver detalles

Preguntas frecuentes

Compruebe nuestro Preguntas frecuentes

Are your transformers ANSI/IEEE compliant?

Yes. All U.S.-bound transformers are designed per ANSI/IEEE C57.12 series. UL listing available upon request.

What is your warranty?

2 years (extendable upon negotiation).

Can you provide third-party test reports?

Yes. We provide complete factory test reports. Third-party witnessed testing can be discussed on a per-project basis.

What is the minimum lead time for emergency orders?

As fast as 15 days for emergency replacements (strategic material reserve).

Do you have a U.S. warehouse or local support?

Main shipping from Shanghai. Remote technical support and on-site service coordination available.

Información y soporte integral

Nuestra sección de preguntas frecuentes cubre productos de transformadores, materiales de aislamiento y especificaciones técnicas, abordando el diseño, las normas de fabricación, el control de calidad y las consultas de logística. Para obtener más asistencia, nuestro equipo técnico está disponible para ayudar.

Contacte con nosotros

PROJECT INQUIRY

Request a transformer quote for Hot-rolled silicon steel sheet

Share the information you already have. Our engineering team will review the requirement and recommend a suitable transformer configuration.

Project-specific configuration Voltage, capacity, cooling and accessories
Technical review and documentation Factory testing and export support available
Global project support Support from initial specification to delivery
[email protected]

Tell us about your project

What do you need us to review?

* Required fields

Your information is used only to respond to this inquiry.

Email